FMEA RPN calculator
Enter failure modes with severity (S), occurrence (O) and detection (D) scores; the tool calculates RPN = S × O × D, ranks the rows, flags those above a threshold and draws a Pareto chart. Rows with high severity can be highlighted regardless of RPN.
Checking your session…
01
How to use it
A
Enter the failure modes and their severity, occurrence and detection scores (1–10), or paste your table as CSV.
B
Read the RPN ranking and the Pareto chart; set the threshold according to your own procedure.
C
Switch on the high-severity option to review serious failures hidden by a low RPN, and download the result as CSV.
02
How is RPN calculated?
The risk priority number is the product of three scores: severity (S), how serious the effect of the failure is; occurrence (O), how often the cause appears; detection (D), how hard it is for current controls to notice the failure before it has an effect. Each score is given from 1 to 10, so RPN lies between 1 and 1000.
Rows are sorted by RPN from largest to smallest. The cumulative share shows what percentage of the total RPN the first n rows make up, which helps you see where to concentrate the work.
03
Why not look at RPN alone?
RPN has known weaknesses: the same number can describe very different situations, the scale is not proportional, and severity is multiplied with equal weight to the other two scores. For this reason many organizations do not use RPN alone; high-severity failures are addressed regardless of RPN.
The tool flags rows with severity 9 and 10 independently of RPN and lists them separately. This is not a weighting method but a safety net. The AIAG-VDA "Action Priority" table is not part of this tool; if you use it, refer to the table in your own guideline.
04
How does monitoring data change the scores?
The detection score (D) expresses how well current controls notice the failure. If continuous measurement such as vibration, temperature or current monitoring can show the failure weeks before its effect, the D score drops and the RPN of that failure mode falls.
An FMEA study and a monitoring plan should therefore be thought of together: failure modes with a high RPN and a measurable physical symptom are the first candidates for monitoring. Do not change D without a real change in controls just to lower the score.
FAQ
- What should the RPN threshold be?
- There is no universal threshold. Values such as 100 are mentioned as examples, but the right threshold depends on your organization's procedure, the scale and the risk. The threshold is a policy choice that decides which rows need action; here it is used only for flagging.
- If two failure modes have the same RPN, which comes first?
- RPN cannot decide it. The general approach is to put the one with higher severity first; at equal RPN the tool sorts the higher-severity row on top. The team should still assess how often the cause occurs and how likely detection is.
- Why are severity 9 and 10 highlighted separately?
- Effects of severity 9–10 usually concern safety or legal compliance. Even when occurrence or detection difficulty looks low, the RPN may stay small; these rows should be handled without looking at RPN. The option keeps them visible in every case.
- How should I assign the scores?
- Take the scale definitions (what 1 and 10 mean) from your own FMEA guideline and have the whole team use the same scale. This tool provides no scale definitions and does not suggest scores.
- How do I bring my table in from Excel?
- Select the failure mode, S, O, D columns in Excel, copy and paste them into the "Paste / import CSV" field (tab-separated text is read). You can take the result out with "Download CSV".
Turn your FMEA into a monitoring plan
Let's look at which of your high-priority failure modes give a measurable symptom and where monitoring could start.