RAID capacity and resilience calculator
Enter the number of disks, the disk capacity and the RAID level: usable space, efficiency, how many disk failures it survives and the probability of hitting an unrecoverable read error (URE) during a rebuild are calculated. Your data never leaves the browser.
Checking your session…
01
How to use
A
Pick the RAID level; enter the number of disks (spares excluded) and the capacity of one disk. Choose TB or TiB to match the disk label.
B
Enter the number of spare disks and the URE rate from your disk's datasheet (for example E = 15 for 1 in 10^15). You may also enter the rebuild speed.
C
Read the usable space, efficiency and tolerated disk failures; look at the rebuild risk and the level comparison table to compare the options.
02
How RAID levels change capacity and resilience
RAID 0 uses all the capacity but offers no redundancy. RAID 1 and RAID 10 mirror the data: half of the capacity (even less in an n-way RAID 1 mirror) goes to redundancy, and in return no parity calculation is needed on writes. RAID 5 gives up one disk and RAID 6 two disks of capacity to parity; efficiency grows with the disk count, but so does the amount of data read in a rebuild.
RAID 50 and RAID 60 stripe several parity groups. With many disks they limit rebuild time and risk to the group size, but every group carries its own redundancy: in the best case more disk failures are tolerated across groups, and in the worst case too many failures in a single group lose the whole array. That is why the tool shows both the minimum and the maximum tolerance.
03
Rebuilds and UREs: why we use a number
When a disk fails and a new one is inserted, the array reads the data on the remaining disks from start to end to regenerate the missing data. In this step, where redundancy has run out, a single unreadable sector (a URE) means that data is lost. With large disks the number of bits read is very high, so even a rate like 10^14 from a datasheet can point to a meaningful probability.
The tool calculates the probability as P = 1 − e^(−B/R). This model assumes errors are independent and evenly spread: in practice drives often behave better than the datasheet rate, but heat, ageing and disks from the same batch can correlate failures. Use the result as a yardstick for comparing options, not as an exact forecast; for critical data think of RAID 6/60, regular scrubbing and a separate backup together.
04
RAID, backup and hot spares
RAID gives continuity against hardware failure; it is not a backup. Accidental deletion, corrupt writes, ransomware and controller faults are mirrored or written into parity. You need a backup in a separate environment, preferably with an immutable copy.
A hot spare starts the rebuild automatically after a failure, which shortens the time without redundancy; it is not added to the capacity. In grouped levels the spare can serve all groups. We give no numbers for write cost: the real effect depends on the controller, the cache, the stripe size and the workload, and has to be measured.
FAQ
- Are the values I enter sent anywhere?
- No. The calculation runs as code in your browser; the values are not sent to any server or stored.
- Why does the capacity I calculate differ from what my operating system shows?
- Vendors count a TB as 10^12 bytes while operating systems often show TiB (2^40 bytes); the tool gives both. Formatting, the file system, metadata and space reserved by the controller are also deducted; that overhead is not included here.
- How should I choose between RAID 5 and RAID 6?
- RAID 5 survives one disk failure and leaves more capacity; RAID 6 survives two. Because rebuilds take long with big disks and many-disk arrays, RAID 6, RAID 10 or RAID 60 is usually preferred for valuable data. The URE probability in the result helps compare them.
- Why is the tolerance for RAID 10 a range?
- One disk of every mirror pair may fail, but if both disks of the same pair fail the array is lost. The guaranteed value is 1 disk; if the failures fall on different pairs it goes up to n/2 disks. RAID 50 and 60 apply the same logic to groups.
- Does a hot spare increase capacity?
- No. A spare waits idle; when it replaces a failed disk the rebuild starts automatically. That is why it is not part of usable space and only enters the denominator of the second efficiency figure.
- What URE rate should I enter?
- Use the "unrecoverable read error" value in your disk's datasheet: E = 14 for 1 in 10^14 bits, 15 for 10^15, 16 for 10^16. If you do not know it, 15 is a reasonable start; try different values of E to see how sensitive the result is.
Is your storage infrastructure resilient?
Let us review your disk arrays, your redundancy levels and your backup and restore times together. In a free discovery call we discuss where you stand and the likely risks.